Countercurrent Supercritical Fluid Fractionation System

Model: SFE-CF

The FLOSN SFE-CF is designed for countercurrent fractionation of suitable liquid feeds using supercritical CO₂. The proposed platform brings a descending liquid phase into contact with an ascending CO₂-rich phase inside a temperature-zoned packed column. Selected components transfer between the phases according to their partition behavior, producing an extract stream and a raffinate stream. Independent feed delivery, CO₂ metering and controlled product withdrawal support the development of continuous fractionation methods for compatible oils, fragrance intermediates and other low-volatility liquid mixtures.

FLOSN / PRODUCT FEATURES

Product Features

8 FEATURES

01Continuous Liquid-Feed Operation

Independent metering is proposed for liquid feed and CO₂ once a stable operating window is established.

02Temperature-Zoned Contact Column

Three controlled thermal zones allow axial temperature profiles to be investigated.

03Replaceable Packing

An accessible column assembly allows packing and distributors to be selected for the intended separation.

04Selectable Feed Locations

Multiple engineered ports support comparison of upper and intermediate feed positions.

05Separate Extract and Raffinate Paths

Independent outlet handling supports product sampling and material-balance measurements.

06Hydraulic Monitoring

Column differential pressure and flow trends are proposed to help identify changes in loading or flooding behavior.

07Optional Reflux and CO₂ Recovery

Dedicated modules can be added after separation trials define the required recycle configuration.

08Pilot-Scale Method Development

The platform is intended to evaluate partitioning, residence behavior and collection strategy before scale-up.

FLOSN / TECHNICAL PARAMETERS

Model & Parameters

SELECTED MODEL

CFD-SA2000

Model-specific specifications
Chamber volume
200 mL
Operating pressure
0–2,000 psi
Power consumption
600 W
Exhaust flow rate
0–1 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
63.5 × 63.5 mm
Chamber dimensions · I.D. × depth (in)
2.5 × 2.5 in
Operating pressure · MPa
0–13.8 MPa
Maximum safe working pressure
2,200 psi (15.2 MPa)
Heating method
PTC electric heating / cartridge electric heating
Overall dimensions · W × D × H
Not specified
SELECTED MODEL

CFD-SA5000

Model-specific specifications
Chamber volume
520 mL
Operating pressure
0–2,200 psi
Power consumption
1,500 W
Exhaust flow rate
0–2 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
114.3 × 50.8 mm
Chamber dimensions · I.D. × depth (in)
4.5 × 2 in
Operating pressure · MPa
0–15.2 MPa
Maximum safe working pressure
2,500 psi (17.2 MPa)
Heating method
PTC electric heating / cartridge electric heating
Overall dimensions · W × D × H
Not specified
SELECTED MODEL

CFD-SA2000*2

Model-specific specifications
Chamber volume
1,080 mL
Operating pressure
0–2,200 psi
Power consumption
1,500 W
Exhaust flow rate
0–2 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
165.1 × 50.8 mm
Chamber dimensions · I.D. × depth (in)
6.5 × 2 in
Operating pressure · MPa
0–15.2 MPa
Maximum safe working pressure
2,500 psi (17.2 MPa)
Heating method
Cartridge heater heating
Overall dimensions · W × D × H
Not specified
SELECTED MODEL

CFD-SA5000*2

Model-specific specifications
Chamber volume
1,860 mL
Operating pressure
0–2,200 psi
Power consumption
2,000 W
Exhaust flow rate
0–0.5 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
215.9 × 50.8 mm
Chamber dimensions · I.D. × depth (in)
8.5 × 2 in
Operating pressure · MPa
0–15.2 MPa
Maximum safe working pressure
2,500 psi (17.2 MPa)
Heating method
Cartridge heater heating
Overall dimensions · W × D × H
Not specified
Shared specifications · all models

Materials & pressure safety

Chamber material
SS316L
Optional materials
Hastelloy C276, Inconel 625, Monel 400, Titanium Grade 2, PTFE lining
Pressure safety system
Electronic pressure monitoring combined with mechanical over-pressure relief protection

Environment & utilities

Operating temperature range
−30 to +60 °C
Operating ambient humidity
20%–70% RH, non-condensing
Power supply
120 / 220 V AC, 50–60 Hz
CO₂ gas requirement
High-purity liquid CO₂ supply; recommended purity >99.9%

Cooling, control & filtration

Cooling system
Integrated closed-loop cooling; the internal chiller loop accelerates cooling and reduces CO₂ consumption
Control system
LCD touchscreen; semi-automated control with programmable timer operation and electronic sensor monitoring
Filtration system
Double T-Filter, Cat. No. 8785; two passes through 0.5 μm filters; >99.5% retention

Samples & chemical compatibility

Compatible sample types
Biological specimens, microscopy samples, hydrogels, aerogels, porous materials, polymers, and other structure-sensitive materials
Compatible solvents
CO₂-miscible solvents commonly used in sample preparation, including ethanol, acetone, methanol, and other laboratory solvents
Chemical compatibility warning
Strongly acidic, strongly alkaline, oxidizing, or highly toxic solvents require prior compatibility evaluation before use
Standard configuration & options

Standard configuration

  • High-pressure viewing window chamber
  • Integrated chamber illumination system
  • Integrated condensation and gas-liquid separation system
  • Non-mechanical CO₂ mixing and exchange system
  • Controlled slow filling and venting system
  • Precision vent flow meter
  • Standard stainless steel CO₂ supply line
  • Anti-static exhaust tubing
  • Replacement O-ring seal kit
  • Installation tool kit
  • User operation manual
  • Factory acceptance test report
  • Warranty and technical support

Optional configurations

  • Interchangeable sample holders
  • Custom sample chamber inserts
  • Magnetic stirring module
  • High-temperature / high-pressure chamber customization
  • Corrosion-resistant alloy chamber upgrade
  • Microscopy sample holder kit

FLOSN / APPLICATIONS

Applications

FLOSN / RESOURCES

Related Documents / Videos