High-Pressure Co-Solvent Metering Pump

Model: HPM-CS

The FLOSN HPM-CS is proposed as a compact, single-channel metering pump for adding liquid modifiers to CO₂-based processes or dosing compatible liquids into pressurized research systems. A dual-plunger drive, front-access fluid path and monitored outlet pressure are combined with a local touchscreen. Its working concept emphasizes reliable priming, manageable solvent handling and reproducible dosing at defined conditions.

FLOSN / PRODUCT FEATURES

Product Features

6 FEATURES

Single-Channel Precision Dosing

The proposed liquid path provides a defined metering channel for modifiers without implying an integrated gradient system.

Front-Accessible Prime and Purge

An accessible purge valve and waste connection simplify bubble removal and solvent changes.

Pressure-Limited Operation

Outlet pressure feedback allows the controller to stop the drive at the selected limit.

Solvent-Specific Fluid Path

Seal, head and inlet-tubing materials are selected together for the intended liquid formulation.

Organized Reservoir Handling

A retained bottle position and removable catch tray reduce loose tubing and improve service access.

Host Ratio Coordination

An external controller can coordinate this pump with a CO₂ pump; verified mixture composition needs actual-flow information.

FLOSN / TECHNICAL PARAMETERS

Model & Parameters

SELECTED MODEL

CFD-SA100

Model-specific specifications
Chamber volume
100 mL
Operating pressure
0–2,000 psi
Power consumption
600 W
Exhaust flow rate
0–1 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
63.5 × 31.75 mm
Chamber dimensions · I.D. × depth (in)
2.5 × 1.25 in
Operating pressure · MPa
0–13.8 MPa
Maximum safe working pressure
2,200 psi (15.2 MPa)
Heating method
PTC electric heating / cartridge electric heating
Overall dimensions · W × D × H
Not specified
SELECTED MODEL

CFD-SA200

Model-specific specifications
Chamber volume
200 mL
Operating pressure
0–2,000 psi
Power consumption
600 W
Exhaust flow rate
0–1 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
63.5 × 63.5 mm
Chamber dimensions · I.D. × depth (in)
2.5 × 2.5 in
Operating pressure · MPa
0–13.8 MPa
Maximum safe working pressure
2,200 psi (15.2 MPa)
Heating method
PTC electric heating / cartridge electric heating
Overall dimensions · W × D × H
Not specified
SELECTED MODEL

CFD-SA500

Model-specific specifications
Chamber volume
520 mL
Operating pressure
0–2,200 psi
Power consumption
1,500 W
Exhaust flow rate
0–2 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
114.3 × 50.8 mm
Chamber dimensions · I.D. × depth (in)
4.5 × 2 in
Operating pressure · MPa
0–15.2 MPa
Maximum safe working pressure
2,500 psi (17.2 MPa)
Heating method
PTC electric heating / cartridge electric heating
Overall dimensions · W × D × H
Not specified
SELECTED MODEL

CFD-SA1000

Model-specific specifications
Chamber volume
1,080 mL
Operating pressure
0–2,200 psi
Power consumption
1,500 W
Exhaust flow rate
0–2 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
165.1 × 50.8 mm
Chamber dimensions · I.D. × depth (in)
6.5 × 2 in
Operating pressure · MPa
0–15.2 MPa
Maximum safe working pressure
2,500 psi (17.2 MPa)
Heating method
Cartridge heater heating
Overall dimensions · W × D × H
Not specified
Shared specifications · all models

Materials & pressure safety

Chamber material
SS316L
Optional materials
Hastelloy C276, Inconel 625, Monel 400, Titanium Grade 2, PTFE lining
Pressure safety system
Electronic pressure monitoring combined with mechanical over-pressure relief protection

Environment & utilities

Operating temperature range
−30 to +60 °C
Operating ambient humidity
20%–70% RH, non-condensing
Power supply
120 / 220 V AC, 50–60 Hz
CO₂ gas requirement
High-purity liquid CO₂ supply; recommended purity >99.9%

Cooling, control & filtration

Cooling system
Integrated closed-loop cooling; the internal chiller loop accelerates cooling and reduces CO₂ consumption
Control system
LCD touchscreen; semi-automated control with programmable timer operation and electronic sensor monitoring
Filtration system
Double T-Filter, Cat. No. 8785; two passes through 0.5 μm filters; >99.5% retention

Samples & chemical compatibility

Compatible sample types
Biological specimens, microscopy samples, hydrogels, aerogels, porous materials, polymers, and other structure-sensitive materials
Compatible solvents
CO₂-miscible solvents commonly used in sample preparation, including ethanol, acetone, methanol, and other laboratory solvents
Chemical compatibility warning
Strongly acidic, strongly alkaline, oxidizing, or highly toxic solvents require prior compatibility evaluation before use
Standard configuration & options

Standard configuration

  • High-pressure viewing window chamber
  • Integrated chamber illumination system
  • Integrated condensation and gas-liquid separation system
  • Non-mechanical CO₂ mixing and exchange system
  • Controlled slow filling and venting system
  • Precision vent flow meter
  • Standard stainless steel CO₂ supply line
  • Anti-static exhaust tubing
  • Replacement O-ring seal kit
  • Installation tool kit
  • User operation manual
  • Factory acceptance test report
  • Warranty and technical support

Optional configurations

  • Interchangeable sample holders
  • Custom sample chamber inserts
  • Magnetic stirring module
  • High-temperature / high-pressure chamber customization
  • Corrosion-resistant alloy chamber upgrade
  • Microscopy sample holder kit

FLOSN / APPLICATIONS