The FLOSN SFE-Pre is designed for preparative extraction and process scale-up studies. The proposed floor-standing platform combines two extraction vessels with higher-capacity CO₂ delivery and independently conditioned separation stages. Removable baskets and assisted closure handling address the practical demands of larger sample loads, while the control system coordinates extraction, product recovery and depressurization. The intended use is the production of research quantities of botanical extracts, oils and other CO₂-soluble fractions, together with the evaluation of operating conditions before further scale-up.

FLOSN / PRODUCT FEATURES

Product Features

8 FEATURES

01Preparative Batch Capacity

A twin-vessel layout is proposed for larger research batches and systematic scale-up studies.

02Staged Separation

Two independently conditioned separators allow different recovery conditions to be investigated.

03Removable Loading Baskets

Basket handling supports repeatable packing and easier material changeover.

04Assisted Closure Handling

Mechanical lifting support is proposed for heavy closures. Access remains conditional on confirmed depressurization.

05Coordinated Process Control

The proposed controller sequences pumping, thermal stages, pressure regulation and product collection.

06Optional CO₂ Recovery

A dedicated recovery package can be assessed against solvent consumption, utility loads and batch frequency.

07Accessible Pump Service Area

The lower base separates pump maintenance from vessel loading and extract collection.

08Scale-Up Data Capture

Logged process conditions support comparison across batch sizes; extraction yield must be measured independently.

FLOSN / TECHNICAL PARAMETERS

Model & Parameters

SELECTED MODEL

CFD-SA2000

Model-specific specifications
Chamber volume
200 mL
Operating pressure
0–2,000 psi
Power consumption
600 W
Exhaust flow rate
0–1 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
63.5 × 63.5 mm
Chamber dimensions · I.D. × depth (in)
2.5 × 2.5 in
Operating pressure · MPa
0–13.8 MPa
Maximum safe working pressure
2,200 psi (15.2 MPa)
Heating method
PTC electric heating / cartridge electric heating
Overall dimensions · W × D × H
Not specified
SELECTED MODEL

CFD-SA5000

Model-specific specifications
Chamber volume
520 mL
Operating pressure
0–2,200 psi
Power consumption
1,500 W
Exhaust flow rate
0–2 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
114.3 × 50.8 mm
Chamber dimensions · I.D. × depth (in)
4.5 × 2 in
Operating pressure · MPa
0–15.2 MPa
Maximum safe working pressure
2,500 psi (17.2 MPa)
Heating method
PTC electric heating / cartridge electric heating
Overall dimensions · W × D × H
Not specified
SELECTED MODEL

CFD-SA10000

Model-specific specifications
Chamber volume
1,080 mL
Operating pressure
0–2,200 psi
Power consumption
1,500 W
Exhaust flow rate
0–2 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
165.1 × 50.8 mm
Chamber dimensions · I.D. × depth (in)
6.5 × 2 in
Operating pressure · MPa
0–15.2 MPa
Maximum safe working pressure
2,500 psi (17.2 MPa)
Heating method
Cartridge heater heating
Overall dimensions · W × D × H
Not specified
SELECTED MODEL

CFD-SA30000

Model-specific specifications
Chamber volume
1,860 mL
Operating pressure
0–2,200 psi
Power consumption
2,000 W
Exhaust flow rate
0–0.5 SLPM

Chamber & operation

Chamber dimensions · I.D. × depth (mm)
215.9 × 50.8 mm
Chamber dimensions · I.D. × depth (in)
8.5 × 2 in
Operating pressure · MPa
0–15.2 MPa
Maximum safe working pressure
2,500 psi (17.2 MPa)
Heating method
Cartridge heater heating
Overall dimensions · W × D × H
Not specified
Shared specifications · all models

Materials & pressure safety

Chamber material
SS316L
Optional materials
Hastelloy C276, Inconel 625, Monel 400, Titanium Grade 2, PTFE lining
Pressure safety system
Electronic pressure monitoring combined with mechanical over-pressure relief protection

Environment & utilities

Operating temperature range
−30 to +60 °C
Operating ambient humidity
20%–70% RH, non-condensing
Power supply
120 / 220 V AC, 50–60 Hz
CO₂ gas requirement
High-purity liquid CO₂ supply; recommended purity >99.9%

Cooling, control & filtration

Cooling system
Integrated closed-loop cooling; the internal chiller loop accelerates cooling and reduces CO₂ consumption
Control system
LCD touchscreen; semi-automated control with programmable timer operation and electronic sensor monitoring
Filtration system
Double T-Filter, Cat. No. 8785; two passes through 0.5 μm filters; >99.5% retention

Samples & chemical compatibility

Compatible sample types
Biological specimens, microscopy samples, hydrogels, aerogels, porous materials, polymers, and other structure-sensitive materials
Compatible solvents
CO₂-miscible solvents commonly used in sample preparation, including ethanol, acetone, methanol, and other laboratory solvents
Chemical compatibility warning
Strongly acidic, strongly alkaline, oxidizing, or highly toxic solvents require prior compatibility evaluation before use
Standard configuration & options

Standard configuration

  • High-pressure viewing window chamber
  • Integrated chamber illumination system
  • Integrated condensation and gas-liquid separation system
  • Non-mechanical CO₂ mixing and exchange system
  • Controlled slow filling and venting system
  • Precision vent flow meter
  • Standard stainless steel CO₂ supply line
  • Anti-static exhaust tubing
  • Replacement O-ring seal kit
  • Installation tool kit
  • User operation manual
  • Factory acceptance test report
  • Warranty and technical support

Optional configurations

  • Interchangeable sample holders
  • Custom sample chamber inserts
  • Magnetic stirring module
  • High-temperature / high-pressure chamber customization
  • Corrosion-resistant alloy chamber upgrade
  • Microscopy sample holder kit

FLOSN / APPLICATIONS